Substance list · ADR

ADR 2025 3.5.1.2 excepted quantity codes

Exemption from most ADR rules for very small quantities per inner and outer packaging.

When it applies
Packages using the code of Table A column (7b)
Entries
6
Version date
2025-01-01
Guide
ADR

Entries

SubstanceCAS TypeCategoryThreshold ConditionsValid
Code E0: in freigestellten Mengen nicht zugelassen otherE0 g (solids) or ml (liquids and gases); for mixed packing the sum of g and ml Not permitted as excepted quantity. For gases, the volume is the water capacity of the inner receptacle and the total water capacity of all inner packagings in one outer packaging. When codes are mixed in one outer packaging, the most restrictive code applies (3.5.1.3). The code for each UN entry is in Table A column (7b). from 2025-01-01
Code E1 otherE1 1000 g (solids) or ml (liquids and gases); for mixed packing the sum of g and ml Maximum net quantity per inner packaging: 30; maximum net quantity per outer packaging: 1000. For gases, the volume is the water capacity of the inner receptacle and the total water capacity of all inner packagings in one outer packaging. When codes are mixed in one outer packaging, the most restrictive code applies (3.5.1.3). The code for each UN entry is in Table A column (7b). from 2025-01-01
Code E2 otherE2 500 g (solids) or ml (liquids and gases); for mixed packing the sum of g and ml Maximum net quantity per inner packaging: 30; maximum net quantity per outer packaging: 500. For gases, the volume is the water capacity of the inner receptacle and the total water capacity of all inner packagings in one outer packaging. When codes are mixed in one outer packaging, the most restrictive code applies (3.5.1.3). The code for each UN entry is in Table A column (7b). from 2025-01-01
Code E3 otherE3 300 g (solids) or ml (liquids and gases); for mixed packing the sum of g and ml Maximum net quantity per inner packaging: 30; maximum net quantity per outer packaging: 300. For gases, the volume is the water capacity of the inner receptacle and the total water capacity of all inner packagings in one outer packaging. When codes are mixed in one outer packaging, the most restrictive code applies (3.5.1.3). The code for each UN entry is in Table A column (7b). from 2025-01-01
Code E4 otherE4 500 g (solids) or ml (liquids and gases); for mixed packing the sum of g and ml Maximum net quantity per inner packaging: 1; maximum net quantity per outer packaging: 500. For gases, the volume is the water capacity of the inner receptacle and the total water capacity of all inner packagings in one outer packaging. When codes are mixed in one outer packaging, the most restrictive code applies (3.5.1.3). The code for each UN entry is in Table A column (7b). from 2025-01-01
Code E5 otherE5 300 g (solids) or ml (liquids and gases); for mixed packing the sum of g and ml Maximum net quantity per inner packaging: 1; maximum net quantity per outer packaging: 300. For gases, the volume is the water capacity of the inner receptacle and the total water capacity of all inner packagings in one outer packaging. When codes are mixed in one outer packaging, the most restrictive code applies (3.5.1.3). The code for each UN entry is in Table A column (7b). from 2025-01-01