Quick answer
In Flanders, get a current SDS in Dutch for every hazardous product you store and use it to manage your store: the pictograms in section 2, the flash point in section 9 and the UN number in section 14 decide your class under VLAREM rubriek 17 (heading 17 of VLAREM II annex 1) and the storage rules of chapter 5.17. Add up your stored quantities per pictogram and compare them with the quantity bands, which often start at 100 kg or 200 kg: class 3 needs a notification, class 2 or 1 a permit. Class 1 sites also keep a register of stored quantities per pictogram.
What it is
Flanders adds its own environmental rules on top of the federal Belgian rules. Workplace safety, the exposure limits, product rules and the SDS language rule stay federal: see Belgium. VLAREM II holds the classification list of installations, environmental quality standards and the conditions for storing hazardous products. Heading 17 of the classification list decides whether your chemical store needs a notification or a permit, based on the hazard pictograms on the label or in section 2 of the SDS. Flanders has no workplace exposure limits of its own.
Does it apply to you?
- You store hazardous products (any pictogram GHS01 to GHS09) in Flanders above the lowest quantity band, often 100 kg or 200 kg, 10 kg for toxic products and 1 kg for explosives.
- You store aerosols or gases in portable receptacles or tanks.
- You hold enough hazardous substances to fall under Seveso (heading 17.2).
- You use organic solvents, emit to air, discharge industrial wastewater or produce hazardous waste.
- Your site is in an industrial zone or in another zone: many thresholds differ between the two.
Managing your safety data sheets
| Task | What applies in Flanders |
|---|---|
| Get an SDS for every hazardous product | Ask your supplier for the SDS of every product you store; VLAREM counts a product when it has a pictogram on the label or in section 2 of the SDS. |
| Check the language and version | The SDS must be in Dutch (federal royal decree of 7 September 2012). Check that you hold the latest version from your supplier. |
| Keep SDS current | Suppliers update the SDS when new information on hazards or risk management becomes available (REACH article 31). Replace old versions: a new pictogram in section 2 can change your storage class. |
| Give workers access | Federal rule: workers must have access to the SDS of the hazardous products they handle (Codex art. VI.1-27). |
| Use them in the risk assessment | Federal rule (Codex art. VI.1-6). For storage, read section 2 (pictograms), section 9 (flash point for the liquid group), section 10 (incompatibilities) and section 14 (UN number). |
| Keep a chemical register | Class 1 sites keep a register per pictogram with the hazard category and quantities of stored products, so the quantities on site are known at any time (art. 5.17.1.2). Seveso sites keep a site plan with product names, pictograms and UN numbers (art. 5.17.1.1). |
| Tanks | Keep the SDS of the stored product with the tank design documents. |
| What an inspector asks | Your permit or notification, quantities per pictogram within what the permit allows, the class 1 register, separation and bunds, and for Seveso sites the site plan. |
What you need to do
- Collect a current Dutch SDS for every stored hazardous product and read the pictograms from section 2.
- Sum your stored hazardous products per pictogram and compare them with the heading 17 bands.
- Apply for a permit or file a notification when your quantities reach class 1, 2 or 3.
- Stay below the quantities your permit allows for each pictogram.
- Use flash point and flammable liquid category to place flammable liquids in the right subheading and liquid group.
- Store products with different pictograms in separate compartments and keep the required distances.
- Keep oxidisers (GHS03) at least 5 m away from flammables (GHS02).
- Provide bunds sized for the liquid group and the storage type.
- Keep a register per pictogram with quantities if your site is class 1.
- Keep an up to date site plan of hazardous stores with product names, pictograms and UN numbers if your site falls under Seveso.
- Replace substances with H340, H350, H350i, H360D or H360F in solvent activities where possible.
- Check the federal exposure limits and carcinogen lists on the Belgium page; they also apply in Flanders.
What NextSDS checks for you
| Check | SDS data used | What it tells you |
|---|---|---|
| Storage thresholds (heading 17) | Section 2 (pictograms, hazard category), section 9 (flash point, density, physical state) | Which permit class your stored quantities reach per pictogram |
| Liquid groups 1, 2 and 3 | Section 2 (flammable category, pictograms), section 9 (flash point) | Which bund, basement and filling rules apply |
| Separation of products | Section 2 (pictograms), section 10 (incompatibilities) | Which products must be stored apart |
| Site plan data | Section 1 (product name), section 2 (pictograms), section 14 (UN number) | The data your hazardous store plan needs |
| Seveso thresholds | Section 2 (classification), section 3 (named substances) | Which products count towards the lower and upper tier |
| CMR substances in solvents and emissions | Section 2 (H statements), section 3 (composition) | Which products trigger substitution or leak detection duties |
Key lists and limits
- Heading 17 storage thresholds (VLAREM II annex 1): quantity bands per pictogram for class 3 (notification), class 2 and class 1 (permit). Official text
- Seveso thresholds (VLAREM II annex 5): tonnage thresholds per CLP hazard category and per named substance for lower and upper tier.
- Storage conditions (VLAREM II chapter 5.17 and annex 5.17.1): separation distances, bunds, tank rules and register duties.
- Surface water quality standards (VLAREM II annex 2.3.1): standards per substance with CAS numbers; above the listed level wastewater counts as containing hazardous substances.
- Air emission limit values (VLAREM II annex 4.4.2): general stack limits per substance with CAS numbers and mass flow triggers.
- Soil standards (VLAREBO annexes): background values and remediation standards for about 50 named substances.
- Federal lists: exposure limits and carcinogen lists apply in Flanders, see Belgium.
Key dates
- 11 December 2026: a pending change to the fugitive VOC rules (article 4.4.6.1.1).
- 1 January 2025: updated tank rules in article 5.17.4.1.16 apply.
- 23 February 2017: the classification list moved into VLAREM II and VLAREM I was repealed. Documents that still cite “VLAREM I annex 1” are outdated.
- 1 June 2015: current rules for storing hazardous solids and liquids (chapter 5.17.4) took effect.
Frequently asked questions
Which SDS data decides the VLAREM storage class?
The hazard pictograms and hazard categories in section 2 decide the subheading. For flammable liquids, the flash point in section 9 sets the liquid group, which decides the bund and filling rules.
In which language must the SDS I receive be in Flanders?
In Dutch. The language rule is federal (royal decree of 7 September 2012) and applies in the whole Flemish Region.
Do I need a chemical register for my store in Flanders?
Class 1 sites must keep a register per hazard pictogram with the hazard category and the quantities of stored hazardous products, so the quantities on site are known at any time. Seveso sites also keep a site plan with product names, pictograms and UN numbers.
Which exposure limits should I compare with section 8 of the SDS in Flanders?
The federal limits of Codex annex VI.1-1, which apply in the whole of Belgium. Flanders has no workplace exposure limits of its own.
What is VLAREM rubriek 17?
Heading 17 of the VLAREM II classification list covers the storage and handling of hazardous products and gases. It sets quantity bands per hazard pictogram that decide whether a store needs a notification (class 3) or a permit (class 2 or class 1).
Is VLAREM I still in force?
No. VLAREM I was repealed on 23 February 2017 and the classification list moved into VLAREM II annex 1. References to “VLAREM I annex 1” are outdated.
How small can a chemical store be before VLAREM applies?
The lowest bands are often 100 kg or 200 kg per pictogram, but only 10 kg for toxic products and 1 kg for explosives. Many thresholds also differ between industrial zones and other zones.
Related frameworks
- Belgium: federal workplace rules, exposure limits and SDS language rule that also apply in Flanders.
- Wallonia: the Walloon equivalent, with storage under heading 63.12.
- Brussels: the Brussels equivalent, with storage under headings 88 and 121.
- Netherlands: neighbouring country where packaged storage follows PGS 15.
- ISO 14001: its compliance obligations include your VLAREM permit conditions.
Official sources
- VLAREM II (Codex Vlaanderen)
- DABM, environmental policy decree
- Omgevingsvergunningsdecreet
- Omgevingsvergunningsbesluit
- VLAREM III (IED installations)
- Materialendecreet and VLAREMA
- Bodemdecreet and VLAREBO
- Navigator, consolidated Flemish environmental law
- Seveso cooperation agreement (FOD WASO)
Based on research of 17 November 2026. This page is not legal advice; always check the official text.